Instrument description
Axiostar plus Technical Data Carl Zeiss
40-815 e 12/01 1-11
1.7 Technical data
(1) Dimensions (width ×
××
× depth ×
××
× height)
Stand with binocular tube......................................................................approx. 200 × 350 × 450 mm
Stand with phototube............................................................................approx. 200 × 350 × 450 mm
Overall height including T2 adapter and CONTAX ARIA SLR camera housing.............. approx. 570 mm
(2) Weight
Axiostar plus with binocular tube..................................................................................approx. 6.7 kg
(3) Ambient conditions
Storage and transport (in packaging):
Permissible ambient temperature ...................................................................................-40 to +70 °C
Permissible relative humidity (without condensation) ........................................................ max. 100 %
Operation:
Permissible ambient temperature ..................................................................................+10 to +35 °C
Permissible relative humidity (without condensation) .......................................................... max. 85 %
Air pressure........................................................................................................800 hPa to 1060 hPa
(4) Operating data
Category of use..............................................................................................................closed rooms
Protection class.................................................................................................................................. I
Protection type ........................................................................................................................... IP 20
Electrical safety.......................................... in compliance with DIN EN 61010-1 (IEC 1010-1) including
.........................................................................................................................CSA and UL directives
Pollution degree ...............................................................................................................................2
Excess voltage category .................................................................................................................... II
Radio interference suppression....................................................in accordance with EN 55011 Class B
Line voltage...................................................................................................... 100 to 240 V (±10 %)
Conversion of the voltage is not necessary due to the wide range power supply!
Line frequency..................................................................................................................50 to 60 Hz
Power consumption.......................................................................................................... max. 65 VA
Output voltage ........................................................................... stabilized, adjustable from 1.5 to 6 V
(5) Fuses in accordance with IEC 127
for 100 − 240 V.........................................................................................T 0.8 A; 250 V; 5 × 20 mm
Comentarios a estos manuales